AIRSTOP Conduit Sleeve
AIRSTOP Conduit Sleeve
To enable vapour retarders and other materials to fulfil their purpose as airtight layer in a construction. These must have air-tight joints at openings for conduits. Warm air finds its way inside a building component through even the smallest of holes in the vapour retarder, where it then condenses. AIRSTOP Conduit Sleeves, bonded air-tight with age-resistant sealing plasters, guarantee that the construction is wind-tight and air-tight.
Available dimensions
| Article number | Width | Length | for cable entry | for cable entry | Carton content | Add |
|---|---|---|---|---|---|---|
| 3AIRKD10 | 150 mm | 150 mm | 15 mm | 22 mm | 1 piece |
|
| 3AIRKD20 | 150 mm | 150 mm | 20 mm | 27 mm | 1 piece |
|
Product data
Field of application
- opening for conduits
Advantages
- extremely flexible
- resistant to ageing
- rubber heat-resistant up to 120 °C (short-term)
To enable vapour retarders and other materials to fulfil their purpose as airtight layer in a construction. These must have air-tight joints at openings for conduits. Warm air finds its way inside a building component through even the smallest of holes in the vapour retarder, where it then condenses. AIRSTOP Conduit Sleeves, bonded air-tight with age-resistant sealing plasters, guarantee that the construction is wind-tight and air-tight.
- Material composition
- EPDM rubber, sealing plaster with age-resistant pure acrylate adhesive
- Temperature resistance
- -40–100 °C
- Working temperature
- -5–40 °C
- Colour
- Black; Sealing plaster white with green imprint
- Age resistance of adhesive
- 30 years
- Storage
- Cool and dry
Processing guideline
Info
Pull the rubber sleeve over the conduit and attach to the air-tight layer (vapour barrier, OSB,…) by the integrated sealing plaster. The diameter of the sleeve selected must have the appropriate dimension for the conduit entry point!The materials used must be free from dust and grease and substrates must be dry and supporting. The greater the pressure applied, the better the performance of the sealing plaster!
Important: To prevent the edge of the rubber hole from tearing, the cable ends should be deburred and the cables cleanly cut. As soon as the edge of the rubber hole tears, sealing is no longer possible!
Instructions
Info
Pull the rubber sleeve over the conduit and attach to the air-tight layer (vapour barrier, OSB,…) by the integrated sealing plaster. The diameter of the sleeve selected must have the appropriate dimension for the conduit entry point!The materials used must be free from dust and grease and substrates must be dry and supporting. The greater the pressure applied, the better the performance of the sealing plaster!
Important: To prevent the edge of the rubber hole from tearing, the cable ends should be deburred and the cables cleanly cut. As soon as the edge of the rubber hole tears, sealing is no longer possible!