Article marked
Error occurred
Please try again later
AIRSTOP FRGD Flexible Pipe Sleeve
AIRSTOP FRGD Flexible Pipe Sleeve
For the permanent airtight sealing of penetrations around pipes in roof pitches up to 45°. This product is extremely flexible and resistant to ageing.
Working temperature: from - 5 °C
Working temperature: from - 5 °C
Available dimensions
Article number | Type | Width | Length | for cable entry | for cable entry | Carton content | Inquiry List |
---|---|---|---|---|---|---|---|
3FRGD100 | FRGD | 350 mm | 350 mm | 100 mm | 125 mm | 4 Stk |
|
3FRGD150 | FRGD | 350 mm | 350 mm | 150 mm | 165 mm | 4 Stk |
|
Product data
Field of application
- openings for conduits
- openings in Roof sloping
Advantages
- extremely flexible
- resistant to ageing
- rubber heat-resistant up to 160° (short-term)
To enable vapour retarders and other materials to fulfil their purpose as airtight layer in a construction these must have air-tight joints at openings for conduits. Warm air finds its way inside a building component through even the smallest of holes in the vapour retarder, where it then condenses. An airtight sealing with AIRSTOP Foldable Conduit Sleeves, guarantee that the construction is windtight and air-tight.
- Material composition
- EPDM rubber and adhesive pad with pure acrylate adhesive
- Temperature resistance
- -40–100 °C
- Working temperature
- -5–40 °C
- Colour
- Black, sealing plaster white with green AIRSTOP imprint
- Age resistance of adhesive
- 30 years
- Storage
- cool and dry
Processing guideline
INFO
Pull the rubber sleeve over the conduit and attach to the air-tight layer (vapour barrier, OSB,…) by the integrated sealing plaster. The diameter of the sleeve selected must have the appropriate dimension for the conduit entry point!Talcum powder or a lubricant can be used if necessary to ease the feeding of the cable/pipe through the sleeve.
The materials used must be free from dust and grease and substrates must be dry and supporting.
The greater the pressure applied, the better the performance of the adhesive tape.
On highly porous and very absorbent substrates such as concrete, plaster, untreated steel or raw wood, we recommend pre-treatment of the substrate with our ISOCELL Primers.
Instructions
INFO
Pull the rubber sleeve over the conduit and attach to the air-tight layer (vapour barrier, OSB,…) by the integrated sealing plaster. The diameter of the sleeve selected must have the appropriate dimension for the conduit entry point!Talcum powder or a lubricant can be used if necessary to ease the feeding of the cable/pipe through the sleeve.
The materials used must be free from dust and grease and substrates must be dry and supporting.
The greater the pressure applied, the better the performance of the adhesive tape.
On highly porous and very absorbent substrates such as concrete, plaster, untreated steel or raw wood, we recommend pre-treatment of the substrate with our ISOCELL Primers.